SK Enterprises Manufacturer of Industrial Magnetizers & Magnetic Instruments — Maharashtra, India

Magnetizer Machines

RCCB / ELCB Calibrator & Testing Machine

An RCCB / ELCB calibrator is an RCCB testing machine that tests residual current breakers — RCCBs, ELCBs and RCBOs — the way they work in service. It passes a controlled residual (earth leakage) current through the breaker and measures the current at which it trips and how quickly it trips. Manufacturers use it to set and check the tripping sensitivity of every breaker, and test laboratories use it to verify breakers against their rated values. SK Enterprises manufactures RCCB / ELCB calibrators for switchgear manufacturers and testing laboratories.

  • Injects a controlled residual current through the breaker under test
  • Measures the tripping current and the trip time
  • For RCCBs, ELCBs and RCBOs used in homes, buildings and industry
  • Digital display of test current and trip time
Tests
Trip current & trip time
Breakers tested
RCCB, ELCB (residual current type), RCBO
Test principle
Residual current passed through one pole, creating the imbalance the breaker must detect
  • Direct from manufacturer
  • Built to your part
  • Application support

Product overview

About RCCB / ELCB Calibrator

How an RCCB / ELCB calibrator works

A residual current breaker compares the current flowing out through the live conductor with the current returning through the neutral. If some current leaks to earth — through a fault or a person — the two no longer balance, and the breaker trips. The calibrator recreates that situation in a controlled way: it passes a set residual current through one pole of the breaker, then measures the current at which it trips and the time it takes to trip.

Tests performed

Test What it checks
No-trip at ½ × IΔn The breaker must not trip at half its rated residual current, so it does not trip without reason in service.
Ramp test The test current rises slowly until the breaker trips; the tripping current must lie between ½ × IΔn and IΔn.
Trip time at IΔn A general-type RCCB must trip within 300 ms at its rated residual current.
Trip time at 2 × and 5 × IΔn Higher leakage must be cleared faster: within 150 ms at 2 × IΔn and 40 ms at 5 × IΔn.

Limits are for general (non-time-delayed) RCCBs to IEC 61008; time-delayed breakers and other standards have their own values.

Made by SK Enterprises

SK Enterprises manufactures RCCB / ELCB calibrators for switchgear manufacturers, testing laboratories and service centres. Tell us the types and ratings of breakers you test and your daily quantity, and we will recommend a configuration. Request a quotation for an RCCB / ELCB calibrator.

Specifications

RCCB / ELCB Calibrator specifications

Typical technical specifications
Breakers tested RCCB, ELCB (residual current type), RCBO
Test principle Residual current passed through one pole, creating the imbalance the breaker must detect
Common rated residual currents (IΔn) 10, 30, 100, 300 and 500 mA
Tests No-trip at ½ × IΔn, ramp to find the tripping current, trip time at 1 ×, 2 × and 5 × IΔn
Trip time Measured in milliseconds
Relevant standards IS 12640, IEC 61008 (RCCB), IEC 61009 (RCBO)

Typical values for this product type, for reference. Exact values depend on grade, size and design — confirm with our team before ordering.

Models & supply from SK Enterprises
Test current range On request
Trip-time range On request
Test waveforms On request
Stations and poles On request
Data and printing On request
Calibration On request
Warranty On request
Lead time On request

Sizes & variants

Common types and variants

Bench calibrators

For laboratories, goods inward and service centres testing one breaker at a time.

Production test benches

Benches for testing and calibrating breakers on the assembly line.

Applications

Applications of RCCB / ELCB Calibrator

  • Production calibration

    Set and check the tripping sensitivity of each breaker during manufacture.

  • Final testing

    Verify the tripping current and trip time of every breaker before it is packed and dispatched.

  • Laboratory testing

    Check samples against their rated residual current and the trip-time limits of the standard.

  • Incoming inspection

    Test purchased RCCBs and RCBOs before they are fitted into panels and distribution boards.

Features & benefits

RCCB / ELCB Calibrator features & benefits

Key features

  • Controlled test current The residual current is set and held steady, or ramped up to find the exact tripping point.
  • Trip-time measurement The breaker is timed from the start of the test current to the moment it trips.
  • Clear digital readout Test current and trip time are shown together, ready to record.
  • Built for daily use Robust construction for continuous use in production and laboratories.

Benefits for your business

  • Safer products Every breaker that leaves the line is proven to trip within its limits.
  • Fewer returns Breakers that trip too early or too late are found before they reach customers.
  • Faster testing One setup measures both tripping current and trip time.
  • Direct from the manufacturer Work with the team that builds the calibrator for configuration, calibration and support.

Get the right RCCB / ELCB Calibrator for your application

Tell us the types and ratings of breakers you test and your daily quantity. Our engineers will recommend the right configuration and send a quotation.

FAQs

RCCB / ELCB Calibrator — frequently asked questions

What does an RCCB / ELCB calibrator do?

It passes a controlled residual (earth leakage) current through a residual current breaker and measures the current at which the breaker trips and how long it takes to trip. These results show whether the breaker will protect people and installations as it should.

What is the difference between an RCCB and an ELCB?

ELCB (earth leakage circuit breaker) is the older, general name. Today's current-operated earth leakage breakers are called RCCBs (residual current circuit breakers). An RCBO is an RCCB with built-in overcurrent protection as well.

Which tests are done on an RCCB?

The usual tests are: no tripping at half the rated residual current (½ × IΔn); a ramp test to find the actual tripping current, which must lie between ½ × IΔn and IΔn; and trip-time tests at 1 ×, 2 × and 5 × IΔn.

How fast must an RCCB trip?

For a general (non-time-delayed) RCCB to IEC 61008, the maximum trip time is 300 ms at the rated residual current, 150 ms at twice that current and 40 ms at five times. Time-delayed (S-type) breakers have different limits.

What is the price of an RCCB / ELCB calibrator?

The price depends on the test current range, the waveforms supported, the number of test stations and the data and printing options. Tell us the breakers you test and your daily quantity, and we will send a quotation.

Related products

All products

Get a quote

Request details for RCCB / ELCB Calibrator

Fill in what you know — our team will follow up with a recommended configuration, price and delivery time.

We’ll call or WhatsApp you on this number.
PDF, Word, Excel or image — max 5 MB.

Prefer to talk?

Call or WhatsApp us with your requirement — we’ll help you choose the right magnetizer and fixture.

WhatsApp Us